Q:
Sean
My question is about determining the minimum number of modules required to turn the inverter on. All modules I have reviewed have "temp coefficient for Voc" but none have "temp coefficient for Vmp"
Example from Canadian Solar module
Temperature Coefficient (Pmax) -0.43% / °C
Temperature Coefficient (Voc) -0.34 % / °C
Temperature Coefficient (Isc) 0.065 % / °C
Is Temperature Coefficient (Pmax) -0.43% / °C used when calculating minimum number of modules required?
Thanks
A:
Most module datasheets do not come with the temperature coefficient of Vmp, however whenever I have seen the manufacturer list the temperature coefficient of Vmp, it has been the same as the temperature coefficient of power, so I just use the temperature coefficient of power.
Thanks,
Sean White